7,788 research outputs found

    Calibration System with Cryogenically-Cooled Loads for CMB Polarization Detectors

    Full text link
    We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody absorbers. The primary advantage of this system is that it can generate a slightly polarized signal (∼100\sim100 mK) in the laboratory; this is at a similar level to that measured by ground-based CMB polarization experiments observing a ∼\sim 10 K sky. It is important to reproduce the observing condition in the laboratry for reliable characterization of polarimeters before deployment. In this paper, we present the design and principle of the system, and demonstrate its use with a coherent-type polarimeter used for an actual CMB polarization experiment. This technique can also be applied to incoherent-type polarimeters and it is very promising for the next-generation CMB polarization experiments.Comment: 7 pages, 9 figures Submitted to RS

    Innovative Demodulation Scheme for Coherent Detectors in CMB Experiments

    Full text link
    We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two- point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.Comment: 3 pages, 4 figure

    Possible Verification of Tilted Anisotropic Dirac Cone in \alpha-(BEDT-TTF)_2 I_3 Using Interlayer Magnetoresistance

    Full text link
    It is proposed that the presence of a tilted and anisotropic Dirac cone can be verified using the interlayer magnetoresistance in the layered Dirac fermion system, which is realized in quasi-two-dimensional organic compound \alpha-(BEDT-TTF)_2 I_3. Theoretical formula is derived using the analytic Landau level wave functions and assuming local tunneling of electrons. It is shown that the resistivity takes the maximum in the direction of the tilt if anisotropy of the Fermi velocity of the Dirac cone is small. The procedure is described to determine the parameters of the tilt and anisotropy.Comment: 4 pages, 4 figures, corrected Fig.

    A self-consistent quantal description of high-K states in the tilted-axis cranking model

    Get PDF
    A self-consistent and quantal description of high-KK bands is given in the framework of the tilted-axis cranking model. (With a θ=90∘\theta=90^{\circ} tilt angle with respect to xx-axis, this cranking model is equivalent to the zz-axis cranking.) The numerical results of the HFB calculations in this framework are compared with experimental data for two quasi-particle excited bands with Kπ=6+K^{\pi}=6^+ in 178^{178}W.Comment: 13 pages, including 5 figures and 1 tabl
    • …
    corecore